Here are instructions how to configure Conduit to use LoRa Network Server provided by The Things Network.
LoRa Network Server Configuration:
LoRa Configuration
{ "SX1301_conf": { "radio_0": { "enable": true, "freq": 867500000 }, "radio_1": { "enable": true, "freq": 868500000 }, "chan_multiSF_0": { "enable": true, "radio": 1, "if": -400000 }, "chan_multiSF_1": { "enable": true, "radio": 1, "if": -200000 }, "chan_multiSF_2": { "enable": true, "radio": 1, "if": 0 }, "chan_multiSF_3": { "enable": true, "radio": 0, "if": -400000 }, "chan_multiSF_4": { "enable": true, "radio": 0, "if": -200000 }, "chan_multiSF_5": { "enable": true, "radio": 0, "if": 0 }, "chan_multiSF_6": { "enable": true, "radio": 0, "if": 200000 }, "chan_multiSF_7": { "enable": true, "radio": 0, "if": 400000 }, "chan_Lora_std": { "enable": true, "radio": 1, "if": -200000, "bandwidth": 250000, "spread_factor": 7 }, "chan_FSK": { "enable": true, "radio": 1, "if": 300000, "datarate": 50000, "freq_deviation": 25000 } }, "gateway_conf" : { "forward_crc_disabled" : true, "forward_crc_error" : false, "forward_crc_valid" : true, "gateway_ID" : "AABBCCDDEEFF1122", <-- change to comply with your hardware "keepalive_interval" : 12, "push_timeout_ms" : 120, "serv_port_down" : 1700, "serv_port_up" : 1700, "server_address" : "router.eu.thethings.network", <-- Select according to your region "stat_interval" : 20, "synch_word" : 52 } }
MTAC LoRa extension module for Conduit. Gateway ID (NODE) is printed in the label of the module.